datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:arete_arix S90 Bus Configuration Rules

arete_arix S90 Bus Configuration Rules free download

Various electronics service manuals

File information:
File name:S90_Bus_Configuration_Rules.pdf
[preview S90 Bus Configuration Rules]
Size:508 kB
Extension:pdf
Mfg:arete_arix
Model:S90 Bus Configuration Rules 🔎
Original:S90 Bus Configuration Rules 🔎
Descr: . Rare and Ancient Equipment arete_arix s90 S90_Bus_Configuration_Rules.pdf
Group:Electronics > Other
Uploaded:07-08-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name S90_Bus_Configuration_Rules.pdf

PRELIMINARY System90IXS Bus Configuration Rules Revision 0.5 INTRODUCTION Bus configuration rules are required for a numbez of reasons. Rules are required to ensure a balance of system resources that minimize perfonnance bottlenecks. Rules are required to ensure that each module is installed in a bus slot with enough priority to prevent module starvation in the event of bus resource overload. Rules are required by cabling restraints that require that certain modules JlC.in$talled .in certain slots. And rules are required to ensure that the power supply is not overloadc(L '.~".' This paper covers configuration rules that deal with the balancing of system',iesoW'ces. and the assignment of modules to ess and esslXA Bus slots. ARBITRATION PRIORITY The Bus Arbiter allocates ess or eSS/XA Bus resources to requesters according to requester priority. The priority of a requester is determined by the bus slot it is installed in. Priorities are assigned to. bus slots by the bus arbiter. The 8f}. Bus Arbiter provides the bus arbiter function for the 8-slot ess Bus and assigns priorities to CSS Bus slots as shown in the following table. For configuration purposes. slots 4 thought 7 are considered mOH priority slots and slots 0 through 3 are considered LOW priority slots. Arbitration Priority CSS Bu~ Slot(s) Highest 7 6 5 4 3 and 0 Lowest 2 and 1 8f}. Bus Arbiter Priority Assignments There are two Bus Arbiters that can provide the bus arbitrationfmiction for the 16..slot eSSor CSSIXA Bus. the 16f}. Bus Arbiter and the 16/4 Bus Arbiter. The 16/2 Bus Arbiter is the original.desi811and may' be used as the ess Bus arbiter in systems with no more than six 68020 Processor 'Modules ,or tw.o 68040 Dual Processor Modules. The 16/4 BuS. Arbiter provides more evenpriority

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
arete_arix System Bus Specification Feb88 - arete_arix IP-07685-00 OS90 Supplemental Software Release 2 May92 - arete_arix MA-99387-00 System90 Model 45 85 Site Preparation Manual Jan90 - arete_arix CSS Bus Spec - arete_arix Asynchronous Communications Interface Adapter Spec May88 - arete_arix System 3000 Memory Module - arete_arix System 3000 Hardware Description May87 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Samsung UN40D5000PG

script execution: 0.01 s